The installation in order
Site check
We confirm gas line size or electrical capacity, venting path and wall space.
Remove the tank
The old tank is drained, disconnected and hauled away.
Mount the unit
The tankless unit is mounted and connected to water, gas or power, and the vent.
Fit service valves
Isolation valves allow a future flush without cutting pipe.
Commission
We test for leaks, check combustion and confirm the temperature setting.
Most of the work is in the site checks. Nothing about the install is tricky once the gas, venting and electrical questions are answered.
What the house needs to supply
| Requirement | What the guidance says | Why it matters |
|---|---|---|
| Gas load | A gas-fired tankless unit adds 175,000 Btu or more | The meter and pipe must handle it |
| Gas line size | In most cases, a three-quarter inch in-house line | A smaller line may need upgrading |
| Electrical | Most electric units need 208 or 240 volts and 50 to 200 amps | Panel capacity can decide the model |
| Water supply | A three-quarter or one inch supply line is typical | Flow depends on pipe size |
| Venting | Use only venting listed for the specific unit | Wrong vent material is a safety issue |
Our tankless water heater page covers sizing, and the sizing math is in our other guides. Here the focus is installation.
Condensing units and drains
High-efficiency condensing units produce acidic condensate that needs a drain, often with a neutralizer. Plan a nearby floor drain or a condensate route. Ask which venting material the unit requires, since condensing models use plastic vent pipe that differs from the metal used on non-condensing ones.
Preparing your home for the install
- Clear the wall and the floor space where the unit will mount.
- Locate the gas shutoff and the electrical panel.
- Move stored items away from the old tank and its venting.
- Confirm how hot water will be handled while the swap is under way.
- Ask your plumber to walk through the day's schedule.
Most installs run a full working day, and the house may be without hot water for much of it. Plan showers and laundry around that.
After the install: what to expect
The unit should deliver steady hot water after a short wait. Some tankless units need a minimum flow to ignite, so very low flows can bring cool bursts. If you notice that, tell the installer, since a recirculation setting or a small adjustment can help.
Keep the model number and the installer's paperwork. The manufacturer's warranty may require evidence of annual flushing, so schedule the first flush a year out and keep the receipt.
Gas or electric: the install differences
| Item | Gas unit | Electric unit |
|---|---|---|
| Fuel supply | Gas line sized for a large load | Dedicated high-amp circuit |
| Venting | Required, using listed vent materials | None |
| Drain | Needed for condensing models | Not usually needed |
| Safety checks | Combustion and leak checks | Electrical load and breaker checks |
| Typical hurdle | Gas line upgrade | Panel capacity |
Neither is better in every home. The right choice depends on the fuel you already have, the capacity of your panel and the space for venting.
Choosing a location for the unit
Tankless units mount on a wall, indoors or outdoors depending on the model. Indoor locations need venting, clearance and a nearby drain for condensing models. Outdoor models save interior space but face freezing and weather exposure.
Choose a spot with room to service the unit and easy access to the gas or electrical supply. A location that is easy to reach makes the yearly flush simpler, which helps the unit last.
Gas safety in Issaquah
Puget Sound Energy's gas safety page says that if you smell gas, leave the area immediately, and not to do anything that may cause a spark. Do not call from inside the house or flip switches. Leave, then call 911 from outside.
Any gas appliance work should use proper venting, shutoffs and leak checks. The gas utility handles leaks at the meter and the street, and a plumber handles the piping inside once the area is safe. Ask the City of Issaquah permit center about permit rules for gas piping work.
Source type: Puget Sound Energy gas safety page
Flush and service plan
A tankless unit needs a yearly flush to clear scale. With the service valves installed, a flush takes under an hour with a pump and cleaning solution. The City of Issaquah's 2021 water quality report lists well hardness at about 3 to 6 grains per gallon by standard conversion, so scale builds more slowly than in very hard water, but it still builds.
Tankless installs on the plateau face the same gas and venting checks, and our Sammamish page covers the dispatch side. The service area page shows the full coverage map.
Planning a tankless install? Call (425) 845-0257.
Call (425) 845-0257Gas, venting and electrical work carry safety and code requirements, and permit rules apply, so most homeowners hire a plumber. Ask the City of Issaquah permit center about your project.
Often it needs to be larger. We measure and calculate before quoting.
A day is common. Gas line upgrades or new venting can add time.
Leave the building and call 911 from outside. Do not use light switches or phones inside.
Condensing units need one for condensate. Non-condensing units usually do not.